SRS Warning Lamp
SRS Warning Lamp
The SRS warning lamp located In the instrument cluster indicates the following:
^ The status of the system readiness check on start-up.
^ A fault within the SRS system.
The input to the SRS warning lamp from the DCU is 12 volts during the readiness test, 0 volts if no fault present and 12 volts if a fault is detected.
The DCU is capable of detecting an open circuit or a short circuit for the SRS warning lamp.
The DCU also stores the following additional information on each fault:
^ A count indicating the number of times the fault occurred.
^ A start and end time for the fault to indicate the duration of the fault.