Diesel Data: Automotive Repair

Canister Purge Control Valve: Service and Repair


Evaporative Emission Canister Purge Valve

Service Repair No - 17.15.39


Removal
1. Disconnect the battery ground cable.
2. Remove the intake manifold casting.

NOTE: Note the fitted position.

3. Release the purge valve from the mounting bracket.
^ Remove the bolt.

CAUTION: Before disconnecting or removing the components, ensure the area around the joint faces and connections are clean. Plug open connections to prevent contamination.

4. Remove the purge valve.
^ Disconnect the 2 hoses.
^ Disconnect the electrical connector.





Installation
1. Connect the purge valve.
^ Connect the hoses.
^ Connect and secure the electrical connector.

NOTE: Align to the position noted on removal.

2. Install the purge valve, align the peg and tighten the bolt to 6 Nm (4 ft. lbs.).
3. Install the intake manifold casting
4. Connect the battery ground cable.