Auxiliary Climate Control Blower Motor Resistor
Blower Motor Resistor
Removal
1 Disconnect the battery ground cable. For additional information, refer to Procedures
2 Remove the floor console upper panel. For additional information, refer to Floor Console Upper Panel Floor Console Upper Panel
3 Disconnect the blower motor resistor electrical connector.
- Reposition the wiring harness.
4 Remove the blower motor resistor.
- Remove the screw.
Installation
1 Install the blower motor resistor.
- Install the screw.
2 Connect the blower motor resistor electrical connector.
- Reposition the wiring harness.
3 Install the floor console upper panel. For additional information, refer to Floor Console Upper Panel Floor Console Upper Panel
4 Connect the battery ground cable. For additional information, refer to Procedures