Daytime Running Lamp: Testing and Inspection
DAYTIME RUNNING LIGHT SYSTEM INSPECTION1. INSPECT MAIN RELAY CIRCUIT
Disconnect the connector from relay and inspect the connector on wire harness side. as shown.
If circuit is as specified, trying replacing the relay with a new one. If the circuit is not as specified, inspect the circuit connected to other parts.
2. INSPECT DAYTIME RUNNING LIGHT NO.2 AND NO. 4 RELAYS CONTINUITY
If continuity is not as specified, replace the relay.
3. INSPECT DAYTIME RUNNING LIGHT RELAY NO.3 CONTINUITY
If continuity is not as specified. replace the relay.