Diesel Data: Automotive Repair

Set Off

MANIFOLD GAUGE SET

SET OFF




1. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE SET
2. DISCONNECT QUICK DISCONNECT ADAPTERS FROM SERVICE VALVES ON REFRIGERANT LINE

HINT: Slide the sleeve of the quick disconnect adapter upward to
Unlock the adapter and remove it from the service valve.

3. INSTALL CAPS TO SERVICE VALVES ON REFRIGERANT LINES