Diesel Data: Automotive Repair

Component Test





1. Disconnect the intake air temperature sensor connector.
2. Measure the resistance between the sensor terminals.





INSTALLATION
1. Apply sealant to threaded portion.

Specified sealant: Loctite 24200 or equivalent

2. Install intake air temperature sensor and tighten it to specified torque.

Sensor tightening torque: 7 N-m (5 ft.lbs.)