Fuel Pressure Control Solenoid: Testing and Inspection
FUEL PRESSURE SOLENOID CHECKNOTE: When disconnecting the vacuum hose always make a mark so that if can be reconnected at original position.
1. Disconnect the vacuum hose from the solenoid valve.
2. Disconnect the harness connector.
3. Connect a hand vacuum pump to the nipple.
4. Connect a battery to the solenoid valve and apply a vacuum to check air-tightness.
5. Measure the resistance between the terminals of the solenoid valve.
Standard value: 29 - 35 Ohms [at 20 °C (68 °F)]
6. If resistance is not within the standard valve replace the fuel pressure solenoid.