Diesel Data: Automotive Repair

Turbocharger Wastegate Solenoid Check

TURBOCHARGER WASTEGATE SOLENOID CHECK





1. Connect a hand vacuum pump to the solenoid valve nipple A.

2. Use a jumper wire to connect between the solenoid valve terminal and battery terminal.




3. Connect and disconnect the jumper wire at the battery negative terminal to apply negative pressure and check tightness.