Fuel Pump Relay: Testing and Inspection
ECCS Relay:
Engine Control Module Relay Test
With 12 Volts DC applied to terminals 1 and 2, CONTINUITY should exist between terminals 3 and 5.
With 0 Volts DC applied to terminals 1 and 2, NO CONTINUITY should exist between terminals 3 and 5