Neutral Safety Switch: Testing and Inspection
^ Disconnect Neutral Switch connector.^ Connect and ohmmeter between both terminals.
^ With the transaxle in NEUTRAL: Continuity should exist.
^ With the transaxle in any gear: NO Continuity should exist.