P1533
Circuit Description
The A/C low side temperature sensor uses a thermistor to control the signal voltage to the PCM. The PCM applies 5 volts on CKT 731 to the sensor. When the sensor is cold, its resistance is high; therefore, the PCM will see a high signal voltage. As the sensor warms, its resistance becomes less and the signal voltage is pulled low through the ground, CKT 470. This diagnostic detects a shorted to ground or open A/C low side temperature sensor circuit by setting the DTC if the PCM monitors a signal voltage, temperature, that is too high or low.
Conditions for Setting the DTC
Test Conditions
^ Ambient Air Temperature between 4°C (39°F) and 99°C (210°F).
^ Ambient Air Temperature sensor failure not indicated by the HVAC controller.
Failure Condition
A/C low side temperature sensor reads less than -37°C (-35°F) or more than 99°C (210°F).
Action Taken When the DTC Sets
^ Disable the A/C compressor clutch.
^ The Malfunction Indicator Lamp (MIL) will not illuminate.
^ No message will be displayed.
Conditions for Clearing the DTC
^ A History DTC will clear after forty consecutive warm-up cycles with no failures of any nor-emission related diagnostic test.
^ A Last Test Failed (current) DTC will clear when the diagnostic runs and does not fail.
^ PCM battery voltage is interrupted.
^ Using a Scan tool.