HVAC System - Manual
REMOVAL PROCEDURE1. Remove the air cleaner and duct assembly.
2. Recover the refrigerant. Refer to Refrigerant, A/C Recovery and Recharging
3. Remove the suction hose nut (3) at the accumulator.
4. Position aside the suction hose from the accumulator.
5. Remove the compressor hose nut (2) from the accumulator..
6. Position aside the compressor hose from the accumulator.
7. Remove the accumulator bracket bolt.
8. Remove the accumulator.
INSTALLATION PROCEDURE
1. Install the accumulator.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the accumulator bracket bolt.
Tighten
Tighten the accumulator bracket bolt to 4 N.m (36 lb in).