Fluid Pump: Service and Repair
Removal Procedure1. Remove the case side cover. Refer to Case Side Cover Replacement.
Notice: Do NOT remove the three bolts which hold the pump together.
2. Remove the oil pump bolts (205-207).
3. Remove the oil pump (200) from the valve body (300).
4. Inspect the oil pump.
Installation Procedure
1. Install the oil pump (200) to valve body (300).
Notice: Refer to Fastener Notice in Service Precautions.
2. Install the oil pump bolts (205-207).
^ Tighten the M6 X 1.0 X 20 bolt to 8 Nm (70 inch lbs.).
^ Tighten the M6 X 1.0 X 85 bolt to 12 Nm (106 inch lbs.).
^ Tighten the M6 X 1.0 X 95 bolt to 12 Nm (106 inch lbs.).
3. Install the case side cover. Refer to Case Side Cover Replacement.