Diesel Data: Automotive Repair

Power Windows - Inoperative - All

POWER WINDOWS INOPERATIVE - ALL

DIAGNOSTIC AIDS
Each door module has a separate battery positive voltage circuit that it uses exclusively for power window motor operation, however, the circuits are all fed by the same PWR WDO circuit breaker located in the rear fuse block. These circuits are in harness connector C3 of each front door module, and in harness connector C2 of each rear door module. If this circuit opens at a point where the separate branches are all joined, all power windows will be inoperative. A short to ground in this circuit will open the PWR WDO circuit breaker, which will also cause all power windows to be inoperative

TEST DESCRIPTION

Steps 1-4:




Steps 5-11:




Steps 12-14:





The Numbers below refer to the step numbers on the diagnostic table.
2. This step determines if this is the correct chart for the symptom.
6. This step determines if a door module is internally shorted to ground, or the door module battery positive voltage circuit, associated with front door modules connector C3 and rear door modules connector C2, is shorted to ground.