Diesel Data: Automotive Repair

Service Port HVAC: Service and Repair

SERVICE PORTS REPLACEMENT

TOOLS REQUIRED
J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE
1. Recover the refrigerant.




2. Remove the service fitting from the line.

INSTALLATION PROCEDURE
1. Lubricate the O-ring using 525 refrigerant oil.




2. Install the service fitting to the line.

NOTE: Refer to Fastener Notice in Service Precautions.

Tighten
Tighten the fitting to 12 N.m (9 lb ft).

3. Recharge the A/C system.
4. Leak test the fittings of the component using the J 39400-A.