Fuel Pump Relay: Testing and Inspection
CAUTION:a. When applying battery voltage to the Control Relay, verify power source connections are to the correct terminals. Otherwise, the Control Relay will be damaged.
b. The following test procedures should be performed in the order instructed. If not, inaccurate results and damage to the relay may occur.
MPI Control Relay:
1. Disconnect the Control Relay electrical connector, and remove the relay.
Testing control relay coils L1 & L2:
2. Check continuity between control relay terminals, with relay coil energized and not energized as shown. To energize coils, L1 and L2, apply battery voltage across terminals 6 and 4.
Testing control relay coils L3:
3. Check continuity between control relay terminals, with relay coil energized and not energized as shown. To energize coil L3, apply battery voltage across terminals 8 and 4.
4. If test results are not satisfactory, replace control relay.