Ignition 1 (Run/Start) Low

When Monitored: With the ignition on.

Set Condition: Absence of 12 volts at the ASDM.

Possible Causes:
- Open fuse
- Short fused ignition switch output circuit
- Open fused ignition switch output circuit
- Loose or poor connections at connector terminals