Diesel Data: Automotive Repair

Passenger A and B Pillar SW Open

When Monitored: With the ignition on.

Set Condition: Both pillar limit switches are open.

Possible Causes:
- Open ground circuit
- Open forward limit switch sense circuit and open reverse limit switch sense circuit
- Faulty limit switches