Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Intake
CAMSHAFT POSITION ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 2 (LEFT SIDE) INTAKE
Removal Procedure
1. Remove the engine mount strut bracket.
2. Disconnect the engine wiring harness electrical connector (2) from the bank 2 intake camshaft position (CMP) actuator solenoid valve.
3. Remove the CMP actuator solenoid valve bolt.
4. Remove the CMP actuator solenoid valve.
5. Inspect the CMP actuator solenoid valve seal for damage and replace as necessary.
Installation Procedure
1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
2. Install the CMP actuator solenoid valve.
Notice: Refer to Fastener Notice.
3. Install the CMP actuator solenoid valve bolt.
Tighten the bolt to 10 Nm (89 lb in).
4. Connect the engine wiring harness electrical connector (2) to the bank 2 intake CMP actuator solenoid valve.
5. Install the engine mount strut bracket.