Positive Crankcase Ventilation Valve: Service and Repair
Positive Crankcase Ventilation Valve Replacement
Removal Procedure
1. Loosen the PCV valve hose clamp (2).
2. Remove the PCV valve hose (3) from the PCV valve.
3. Remove the PCV valve (1) from the cylinder head.
Installation Procedure
Notice: Refer to Component Fastener Tightening Notice.
1. Install the PCV valve (1) into the cylinder head.
Tighten the PCV valve to 27 N.m (13 lb ft).
2. Connect the PCV valve hose (3) to the PCV valve (1).
3. Secure the PCV valve hose with one clamp (2).