Instrument Panel Insulator Panel Replacement - Left Side (LHD)
Instrument Panel Insulator Panel Replacement - Left Side (LHD)
Removal Procedure
1. Remove the diagnostic plug to I/P lower trim plate assembly retaining screws (2).
2. Remove the diagnostic plug (1) from the I/P lower trim plate assembly (3).
3. Grasp the I/P lower trim plate assembly (1) and carefully pull downward to disengage the retaining clips.
4. Remove the I/P lower trim plate assembly (1).
Installation Procedure
1. Install the diagnostic plug (2) to the I/P lower trim plate assembly (1).
2. Align the I/P lower trim plate assembly (1) to the I/P.
3. Install the I/P lower trim plate assembly (1) to the I/P by pushing in the area of the retaining clips (2).
4. Ensure all clips are located correctly.
5. Install the diagnostic plug (1) to the I/P lower trim plate assembly (3).
Notice: Refer to Fastener Notice (Fastener Notice) .
6. Install the diagnostic plug to I/P lower trim plate assembly retaining screws (2).
Tighten the screws (1) to 2 N.m (18 lb in).