Diesel Data: Automotive Repair

130. Water Outlet Installation



Water Outlet Installation






Important: Ensure a new rubber O-ring and seal is used when installing the water outlet housing.


1. Install the coolant outlet housing (2) to the intake manifold.

Notice: Refer to Fastener Notice (Fastener Notice) .

2. Install the coolant outlet housing to intake manifold retaining bolts (1).

Tighten the bolts to 10 Nm (89 lb in).