Inflatable Restraint Instrument Panel Module Replacement
Inflatable Restraint Instrument Panel Module Replacement
Removal Procedure
Caution: Refer to SIR Inflator Module Handling and Storage Caution (SIR Inflator Module Handling and Storage Caution).
1. Disable the SIR system. Refer to SIR Disabling and Enabling (Service and Repair).
2. Remove the instrument panel (I/P) compartment (2). Refer to Instrument Panel Compartment Replacement (Service and Repair).
3. Disconnect the I/P module connector (1).
4. Remove the I/P module fasteners (2,3).
5. Remove the inflatable restraint I/P module (1).
6. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling and Scrapping (Service and Repair).
Installation Procedure
1. Install the inflatable restraint I/P module (1).
Notice: Refer to Fastener Notice .
2. Install the mounting fasteners (2,3) to the I/P module.
Tighten fasteners to 20 N.m (15 lb ft).
3. Connect the I/P module connector (1).
4. Install the I/P compartment (2). Refer to Instrument Panel Compartment Replacement (Service and Repair).
5. Enable the SIR system. Refer to SIR Disabling and Enabling (Service and Repair).