Diesel Data: Automotive Repair

Fault Conditions




P1460

Immobilizer Active. NOTE. If new T7, MIU or TWICE module, program code in TWICE.







Fault symptoms
- Engine will not start.

On-Board Diagnostics

Type of diagnosis:
- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.

Enable criteria:
- Ignition ON

Fault criteria:
- Immobilizer code from TWICE incorrect or missing.

Dependents:
- None.

System reaction to a fault:
- Fuel shut-off.

OK report:
- Enable criteria fulfilled. Fault criteria not fulfilled within 60 s.

Fault handling: (See Fault handling III, Other emission-related components and functions for more information.) Fault Handling III, Other Emission-Related Component & Function
- Type III.
- CHECK ENGINE does not go on.

Diagnostic help
Fault diagnosis concerns unprogrammed transponder or unprogrammed immobilizer code in TWICE.

Functions in the diagnostic tool related to the fault:
- Group FUEL CUT, reading: Trouble Code Detected, unit ON/OFF

See also the description of readings under Menu "Read Values" for more information. Tech 2 Menu Structure, DTC Menu, Read Value, Activate, Sys Info


NOTE: Program immobilizer code in TWICE after fitting new Control module (Trionic T7, TWICE or MIU).