4. Battery Check During Service
4. Battery check during service1. Remove the battery cover.
2. Check the battery electrolyte level. The battery cannot be topped up with electrolyte. It must be replaced if the level is too low.
NOTE: The electrolyte level is checked through an indicator window on the battery that appears white if the level is too low. If the electrolyte level is sufficiently high, the indicator window appears black.
3. Remove the cover from the underhood electrical centre (UEC).
4. Put the car in transport mode - see Transport mode/customer mode of car's electrical system.
5. Switch off all consumers and check that the text "Transport fuse removed" appears in the main instrument unit. Then remove the ignition key from the ignition switch.
NOTE: Some diagnostic trouble codes may be generated if the battery check is carried out with the key in the ignition switch.
6. Remove fuse 30. Wait at least 20 seconds before connecting the battery analyser.
7. Connect the battery analyser with the red clamp to the positive terminal (+) and the black clamp to the negative terminal (-). Incorrect polarity will not damage the analyser. Make sure that the clamps make as good contact as possible.
Follow the instructions on the analyser display.
NOTE: Once both clamps are connected, the analyser activates automatically. For a more detailed description on analyser use, see the analyser's user manual.
8. Under "SELECT TEST", you choose whether the battery is connected to the car's electrical system ("IN VEHICLE") or not ("OUTSIDE VEHICLE"). Select ("IN VEHICLE") since the battery is connected to the car.
9. Under "BATTERY TYPE", select whether the battery is factory-fitted ("SAAB BATTERY") or a replacement battery from another manufacturer ("NON-SAAB").
10. Confirm "SELECT TEST BY SAE (A)" if the battery's cold starting current is specified as per CCA (SAE or EN) standard. For batteries specified as per DIN standard, select and confirm "SELECT TEST BY DIN (A)".
NOTE: The DIN standard can be selected when the analyser is used to test replacement batteries that are not specified according to SAE or EN.
11. Enter the cold starting current (CCA) for the battery in question.
For Saab's factory-fitted batteries, this value if found in large text on the label on the top of the battery.
60 Ah = 580 CCA
70 Ah = 700 CCA
85 Ah = 750 CCA
After selecting and confirming the value, battery measurement starts automatically.
Under certain voltage and conductance conditions, the analyser will require information on whether the test is being performed before or after the battery has been charged in order to assess it correctly.
Select "BEFORE CHARGE" or "AFTER CHARGE".
Follow the action suggested by the battery analyser:
- Good battery = Battery is good. No action.
- Good, recharge battery = Battery must be charged, but not replaced.
- Replace battery = Battery must be replaced.
12. Note the test code if the analyser has indicated that the battery must be replaced within the warranty period. The test code from this measurement must then accompany the warranty claim (for more information, see Warranty policy).
13. Fit fuse 30 and fuse 37 (moved from TRANSPORT to position 37). Put the car in customer mode - see Transport mode/customer mode of car's electrical system.
14. Fit the cover over the underhood electrical centre (UEC).
15. Fit the battery cover.
16. Carry out procedures after disconnecting the battery.