Diesel Data: Automotive Repair

Removal





2AZ-FE EMISSION CONTROL: PURGE VALVE: REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected Testing and Inspection.

2. REMOVE NO. 1 VACUUM SWITCHING VALVE ASSEMBLY

(a) Disconnect the connector.





(b) Remove the wire harness clamp.

(c) Disconnect the 2 purge line hoses from the No. 1 vacuum switching valve assembly.

(d) Remove the No. 1 vacuum switching valve assembly from the air cleaner hose.