Variable Induction Control Actuator: Service and Repair

Tumble Generator Valve Actuator

REMOVAL

RH SIDE




1. Disconnect the ground cable from battery.
2. Disconnect the connector from tumble generator valve actuator RH.




3. Remove the tumble generator valve actuator RH.

LH SIDE




1. Disconnect the ground cable from battery.
2. Remove the intercooler.
3. Disconnect the connector from tumble generator valve actuator LH.




4. Remove the tumble generator valve actuator LH.

INSTALLATION

RH SIDE
Install in the reverse order of removal.

LH SIDE
Install in the reverse order of removal.