Diesel Data: Automotive Repair

Purge Damper

Purge Damper

REMOVAL

WARNING: Place "NO OPEN FLAMES" signs near the working area.

1. Remove the bolts which secure the purge damper to the purge damper bracket.






2. Disconnect the evaporation hose from the purge damper and remove the purge damper.






INSTALLATION
Install in the reverse order of removal.

Tightening torque: 13 N.m (1.3 kgf.m, 9.6 ft.lb)






INSPECTION
1. Check that the purge damper has no deformation, cracks or other damages.
2. Check that the evaporation hose has no cracks, damage or loose part.