Bell Housing: Service and Repair
REMOVAL1. Remove oil seal.
NOTE: Never reuse removed oil seal.
2. Remove oil reservoir plate with three magnets by removing bolts.
3. Remove roller bearing retainer by removing bolt.
4. Remove cylindrical roller bearing, using Special Tools (A): 09942-15510, (B): 09941-54911 (remover), and (C): 09921-26010 (caller), or equivalent.
NOTE: Never reuse removed bearing.
5. Remove integrated needle roller bearing with race.
INSPECTION
- Check pan for particles.
- Remove magnets and use them to collect any chips.
- Inspect oil reservoir plate for any chips and particle collected on magnet.
- Inspect them carefully to find out the type of wear on transmission.
Steel (magnetic) Wear of bearing, gear and plate
Brass (nonmagnetic) Wear of bush
INSTALLATION
1. Apply A/T fluid to integrated needle roller bearing with race.
Race dimension
Outside diameter: 45.7 mm (1.80 inch)
Inside diameter: 30.0 mm (1.18 inch)
Thickness: 3.0 mm (0.12 inch)
2. Install integrated needle roller bearing to transmission case.
3. Apply A/T fluid to outer surface of cylindrical roller bearing.
4. Tap cylindrical roller bearing, using Special Tools (A): 09924-74510 and (B): 09944-88210, or equivalent.
5. Tighten roller bearing retainer with bolt.
Tightening Torque (a): 13 Nm (114 inch lbs.)
6. Install transmission lubrication tube and clamp.
7. Tighten them with bolt.
Tightening Torque (b): 5.5 Nm (48 inch lbs.)
8. Tighten oil reservoir plate (with three magnets installed) with bolts.
Tightening Torque (b): 5.5 Nm (48 inch lbs.)