Removal and Installation
Evaporator (Cooling Unit)REMOVAL
1. Disconnect negative (-) cable at battery.
2. Disable air bag system.
3. Recover refrigerant by using recovery and recycling equipment. Be sure to follow the instruction manual for the equipment. The amount of compressor oil removed must be measured and the same amount added to the system.
4. Remove blower motor unit.
5. Disconnect A/C amplifier and thermistor wire couplers.
6. Disconnect compressor suction pipe, receiver/dryer outlet pipe and drain hose from evaporator (cooling unit).
NOTE: As soon as above hose and pipe are disconnected, cap opened fittings so that moisture and dust may not enter cooling unit.
7. Remove evaporator with evaporator case.
8. Remove A/C amplifier from lower case.
INSTALLATION
1. Reverse removal sequence to install thermistor.
2. Enable air bag system.
3. Evacuate and charge system according to previously described procedure.