Positive Crankcase Ventilation Valve: Service and Repair

PCV Valve Removal and Installation

Removal

1. Remove air cleaner.
2. Disconnect PCV hose from PCV valve.
3. Remove PCV valve from cylinder head cover.

Installation

Reference: PCV Valve Inspection

Reverse removal procedure for installation noting the following.
^ Apply sealant to thread part of PCV valve (1).
"A": Water tight sealant 99000-31250 SUZUKI Bond No.1207F

^ Tighten PCV valve to specified torque.

Tightening torque
PCV valve a: 27 Nm (2.7 kgf-m, 19.5 ft. lbs.)




^ Connect PCV hose to PCV valve securely.