Removal and Installation
Expansion Valve Removal and Installation
HVAC Unit Components:Manual A/C
Removal
1) Recover refrigerant from the A/C system with recovery and recycling equipment referring to "Recovery" in Service and Repair Operation Procedure for Refrigerant Charge:Manual A/C.
2) Loosen a bolt (1) and remove pipes from expansion valve (2).
3) Loosen bolts (3) and remove expansion valve.
Installation
Expansion Valve Inspection:Manual A/C
Reverse removal procedure noting the following instructions.
- Apply compressor oil to O-ring of expansion valve and pipes.
- Tighten expansion valve bolts to specified torque.
Tightening torque
Expansion valve bolt 4.5 Nm (0.45 kgf-m, 3.5 lbf-ft)
- Evacuate and charge the A/C system referring to "Evacuation" and "Charge" in Service and Repair Operation Procedure for Refrigerant Charge:Manual A/C.