Shift Interlock: Service and Repair
COMPONENT AND CIRCUIT
INSPECTION OF ELECTRIC CONTROL COMPONENTS
1. INSPECT SHIFT LOCK CONTROL COMPUTER
Do not disconnect the computer connector. Measure the voltage and continuity between terminals.
2. INSPECT SHIFT LOCK SOLENOID
a. Disconnect the solenoid connector.
b. Using an ohmmeter, measure the resistance between terminals.
Standard resistance: 21 - 27 ohm
c. Apply battery voltage between terminals. Check that an operation noise can be heard from the solenoid.
3. INSPECT KEY INTER LOCK SOLENOID
a. Disconnect the solenoid connector.
b. Using an ohmmeter, measure the resistance between terminals.
Standard resistance: 12.5 16.5 ohm
c. Apply the battery voltage between terminals. Check that an operation noise can be heard from the solenoid.
4. INSPECT SHIFT LOCK CONTROL SWITCH
Check whether there is continuity between each terminals.