Evaporative Emissions System: Specifications
4A-FE ENGINE
EVAP BVSV
Below 40°C (104°F) Closed (EVAP Disabled)
Above 54°C (129°F) Open (EVAP Enabled)
Engine Vacuum At Idle 450 mmHg (17.72 in.Hg, 60 kPa) or more
4A-GE ENGINE
EVAP BVSV
Below 35°C (95°F) Closed (EVAP Disabled)
Above 54°C (129°F) Open (EVAP Enabled)
Engine Vacuum At Idle 450 mmHg (17.72 in.Hg, 60 kPa) or more