Fuel Shut-off Solenoid: Testing and Inspection
1. Disconnect the Fuel-cut Solenoid and unscrew it from the carburetor.2. Connect battery current to the terminals as shown.
Testing Fuel-Cut Solenoid Operation - Case Grounded:
3. When connection is made, a "click" should be heard and felt as the plunger retracts.
4. If a problem is found, replace the Fuel-cut Solenoid.
5. Connect battery current to terminals as shown and repeat step 3.
Testing Fuel-Cut Solenoid Operation - Harness Grounded:
6. If a problem is found, replace the Fuel-cut Solenoid.
7. Check the O-ring for damage and replace if necessary.
8. Reinstall the valve and reconnect the connector.
NOTE: Refer to COMPUTERIZED ENGINE CONTROLS for a complete test of the Deceleration Fuel-Cut System.