Service Hints
H 2 HEADLIGHT CLEANER RELAY5-2 : Closed with the Ignition SW at ON position and headlight Cleaner SW at ON position and light control SW at HEAD position
1-GROUND : Approx. 12 Volts with the ignition SW at ON position
3-GROUND : Always continuity
5-GROUND : Always approx. 12 Volts