Radiator Cooling Fan Motor Relay: Testing and Inspection
INSPECTION1. REMOVE RELAY BOX COVER
2. INSPECT NO.1 COOLING FAN RELAY
a. Remove the No.1 cooling fan relay. (Marking: FAN NO.1)
b. Inspect the No.1 cooling fan relay continuity.
1) Using an ohmmeter, check that there is continuity between terminals 1 and 2.
If there is no continuity, replace the relay.
2) Check that there is no continuity between terminals 3 and 5.
If there is continuity, replace the relay.
c. Inspect the No.1 cooling fan relay operation.
1) Apply battery positive voltage across terminals 1 and 2.
2) Using an ohmmeter, check that there is continuity between terminals 3 and 5.
If there is no continuity, replace the relay.
d. Reinstall the No.1 cooling fan relay.
3. INSPECT NO.2 COOLING FAN RELAY
a. Remove the No.2 cooling fan relay. (Marking: FAN NO.2)
b. Inspect the No.2 cooling fan relay continuity.
1) Using an ohmmeter, check that there is continuity between terminals 1 and 2.
If there is no continuity, replace the relay.
2) Check that there is continuity between terminals 3 and 4.
If there is no continuity, replace the relay.
3) Check that there is no continuity between terminals 3 and 5.
If there is continuity, replace the relay.
c. Inspect the No.2 cooling fan relay operation.
1) Apply battery positive voltage across terminals 1 and 2.
2) Using an ohmmeter, check that there is no continuity between terminals 3 and 4.
If there is continuity, replace the relay.
3) Check that there is continuity between terminals 3 and 5.
If there is no continuity, replace the relay.
d. Reinstall the No.2 cooling fan relay.
4. INSPECT NO.3 COOLING FAN RELAY
a. Remove the No.3 cooling fan relay. (Marking: FAN NO.3)
b. Inspect the No.3 cooling fan relay continuity.
1) Using an ohmmeter, check that there is continuity between terminals 1 and 2.
If there is no continuity, replace the relay.
2) Check that there is no continuity between terminals 3 and 5.
If there is continuity, replace the relay.
c. Inspect the No.3 cooling fan relay operation.
1) Apply battery positive voltage across terminals 1 and 2.
2) Using an ohmmeter, check that there is continuity between terminals 3 and 5.
If there is no continuity, replace the relay.
d. Reinstall the No.3 cooling fan relay.
5. REINSTALL RELAY BOX COVER
INSPECTION
1. REMOVE NO.2 COOLING FAN RELAY FROM RELAY BLOCK NO.8
2. REMOVE NO.3 COOLING FAN RELAY FROM RELAY BLOCK NO.8
3. INSPECT NO.2 COOLING FAN RELAY (Marking: A.C FAN NO.2) CONTINUITY
If continuity is not as specified, replace the relay.
4. INSPECT NO.3 COOLING FAN RELAY (Marking: A.C FAN NO.3) CONTINUITY
If continuity is not as specified, replace the relay.