Inspection
INSPECTION1. INSPECT SLIDING ROOF LIMIT SWITCH
a. Inspect the sliding roof limit switch continuity.
If the continuity is not as specified, replace the switch.
2. INSPECT SLIDING ROOF DRIVE GEAR SUB-ASSY
a. Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, and check that the motor turns clockwise (moves to the close side).
b. Reverse the polarity, check that the motor turns counterclockwise (moves to the open side).
If the operation is not as specified, replace the motor.
3. INSPECT SLIDING ROOF MOTOR CIRCUIT BREAKER
a. With the sliding roof in the fully opened position, hold the sliding roof switch in the "OPEN" side and check that there is circuit breaker operating noise within 10 to 60 seconds.
b. With the sliding roof in the fully opened position, hold the sliding roof switch in the "CLOSE" side and check that the sliding roof begins to close within 60 seconds.
If the operation is not as specified, replace the motor.
4. INSPECT POWER MAIN RELAY
a. Inspect power main relay continuity.
If continuity is not as specified, replace the relay.