Leak Detection Solenoid: Service and Repair
REMOVAL1. REMOVE VSV FOR CCV
a. Remove the 3 bolts and canister assembly.
b. Remove the 2 bolts and canister bracket assembly.
c. Remove the screw and VSV.
d. Remove the O-ring from the VSV.
2. INSPECT VSV FOR CCV
INSTALLATION
INSTALL VSV FOR CCV
a. Install a new O-ring to the VSV.
b. Install the VSV with the screw.
c. Install the canister bracket assembly with the 2 bolts.
Torque: 5.4 Nm (55 kgf.cm, 48 in.lbf)
d. Install the canister with the 3 bolts.
Torque: 19 Nm (193 kgf.cm, 14 ft.lbf)