Daytime Running Lamp Relay: Testing and Inspection
INSPECT DAYTIME RUNNING LIGHT RELAY (MAIN) CIRCUIT
Disconnect the connector from the relay and inspect the connector on the wire harness side, as shown in the chart.
If circuit is as specified, try replacing the relay with a new one.
If circuit is not as specified, inspect the circuits connected to other parts.
INSPECT NO.4 DAYTIME RUNNING LIGHT RELAY (Marking: DRL NO.4) CONTINUITY
If continuity is not as specified, replace the relay.