Without Scan Tool
CLEAR DTCsWhen not using the hand-held tester:
HINT: Remove the P CON MAIN fuse to erase DTCs C2300, C2301, C2303, C2304, C2305, C2306, and C2307 because they cannot be erased with the hand-held tester.
1. Turn the power switch off.
2. Remove the P CON MAIN fuse (7.5 A) for 60 seconds or more, and then reconnect it.
3. Turn the power switch on (IG).
4. Check that no DTCs are output.