Hazard Warning Switch: Testing and Inspection
HAZARD WARNING SIGNAL SWITCH ASSYa. Measure the resistance according to the value(s) in the table.
b. Connect the positive (+) lead from the battery to terminal 8 and the negative (-) lead to terminal 9, then check that the illumination comes on.
OK: Illumination comes on.