Diesel Data: Automotive Repair

Battery Current Sensor: Testing and Inspection








P112 HYBRID BATTERY CONTROL: BATTERY CURRENT SENSOR:

INSPECTION

1. INSPECT BATTERY CURRENT SENSOR





(a) Inspect the resistance.
(1) Measure the resistance between terminals 1 (VIB) and 2 (GIB).
Standard resistance:





If the the results are not as specified, replace the battery current sensor.
(2) Measure the resistance between terminals 1 (VIB) and 3 (IB).
Standard resistance:





If the results are not as specified, replace the battery current sensor.
(3) Measure the resistance between terminals 2 (GIB) and 3 (IB).
Standard resistance:
0.2 kOhms or less

NOTE: Even if the probes are changed around, the resistance will not vary.

If the result is not as specified, replace the battery current sensor.