Battery Current Sensor: Testing and Inspection
P112 HYBRID BATTERY CONTROL: BATTERY CURRENT SENSOR:
INSPECTION
1. INSPECT BATTERY CURRENT SENSOR
(a) Inspect the resistance.
(1) Measure the resistance between terminals 1 (VIB) and 2 (GIB).
Standard resistance:
If the the results are not as specified, replace the battery current sensor.
(2) Measure the resistance between terminals 1 (VIB) and 3 (IB).
Standard resistance:
If the results are not as specified, replace the battery current sensor.
(3) Measure the resistance between terminals 2 (GIB) and 3 (IB).
Standard resistance:
0.2 kOhms or less
NOTE: Even if the probes are changed around, the resistance will not vary.
If the result is not as specified, replace the battery current sensor.