Automatic Air Conditioning System
AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System): 32: Air Inlet Damper Position Sensor Circuit
DTC 32 - Air Inlet Damper Position Sensor Circuit
DESCRIPTION
This sensor detects the position of the air inlet control servo motor (recirculation damper servo sub-assembly) and sends the appropriate signals to the A/C amplifier. The position sensor is built in the air inlet control servo motor (recirculation damper servo sub-assembly).
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT AIR CONDITIONING AMPLIFIER (TPI - SG-2)
(a) Remove the A/C amplifier with the connectors still connected.
(b) Turn the ignition switch to the ON position.
(c) Change the RECIRC/FRESH setting to activate the air inlet control servo motor (recirculation damper servo sub-assembly).
(d) Measure the voltage according to the value(s) in the table below.
Standard voltage:
HINT: As the air inlet control servo motor (recirculation damper servo sub-assembly) moves from the RECIRC side to the FRESH side, the voltage decreases gradually without interruption.
Result:
C -- REPLACE AIR CONDITIONING AMPLIFIER
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
A -- Continue to next step.
2. INSPECT AIR INLET CONTROL SERVO MOTOR (RECIRCULATION DAMPER SERVO SUB-ASSEMBLY)
(a) Remove the air inlet control servo motor (recirculation damper servo sub-assembly).
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(c) Measure the resistance according to the value(s) in the table below.
HINT: For details, regarding operation of servo motor. (Automatic Air Conditioning System)
Standard resistance:
HINT: As the air inlet control servo motor (recirculation damper servo sub-assembly) moves from the FRESH side to the RECIRCULATION side, the resistance decreases gradually without interruption.
NG -- REPLACE AIR INLET CONTROL SERVO MOTOR
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (AIR INLET CONTROL SERVO MOTOR - AIR CONDITIONING AMPLIFIER)
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE AIR CONDITIONING AMPLIFIER