Removal
3MZ-FE CHARGING: GENERATOR:
REMOVAL
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
2. REMOVE GENERATOR ASSEMBLY
(a) Remove the wire harness clamp.
(b) Disconnect the generator connector.
(c) Open the terminal cap, remove the nut and disconnect the generator wire.
(d) Loosen the 2 bolts.
(e) Loosen the bolt to lessen the tension of the V belt.
(f) Remove the 2 bolts and generator.