Programming and Relearning
WINDSHIELD / WINDOWGLASS: POWER WINDOW CONTROL SYSTEM: INITIALIZATION
INITIALIZATION
1. INITIALIZE POWER WINDOW REGULATOR MOTOR
NOTE: Resetting the power window motor (initializing the pulse sensor) is necessary when the battery terminal is disconnected; when the power window regulator master switch, power window regulator switch, wire harness, power window regulator and power window motor are replaced or removed/installed; or when the FR DOOR fuse, ECU-B fuse and ECU-IG No.1 fuse are replaced. AUTO operation function, jam protection function and remote operation function via the power window regulator master switch do not operate without resetting.
(a) Ignition switch on (IG).
(b) (Power window can be partially or fully open.)
(c) Close the power window by holding the Auto UP knob ON.
(d) Continue to hold the Auto UP knob ON a minimum of 1 second after the power window completely closes.
(e) Release the Auto UP knob.
HINT: Front passenger must be initialized from actual multiplex network switch assembly. After initialization operation (from the multiplex network master switch assembly to the multiplex network switch assembly) will be allowed.