Installation
U250E AUTOMATIC TRANSAXLE: SPEED SENSOR: INSTALLATION
INSTALLATION
1. INSTALL SPEED SENSOR (NC SENSOR)
(a) Coat a new O-ring with ATF and install it to the speed sensor.
(b) Install the speed sensor with the bolt.
Torque: 8.8 Nm (90 kgf-cm, 78in-lbf)
(c) Connect the speed sensor connector.
2. INSTALL SPEED SENSOR (NT SENSOR)
(a) Coat a new O-ring with ATF and install it to the speed sensor.
(b) Install the speed sensor with the bolt.
Torque: 8.8 Nm (90 kgf-cm, 78in-lbf)
(c) Connect the speed sensor connector.
3. INSTALL AIR CLEANER CASE SUB-ASSEMBLY Installation
4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY Installation
5. INSTALL AIR CLEANER INLET ASSEMBLY Installation
6. INSTALL BATTERY Installation
7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Torque: 6.9 Nm (70 kgf-cm, 61in-lbf)