Diesel Data: Automotive Repair

Installation








1AR-FE ENGINE CONTROL: KNOCK SENSOR: INSTALLATION

INSTALLATION

1. INSTALL KNOCK SENSOR





(a) Install the sensor with the bolt so that the sensor is angled as shown in the illustration.
Torque: 20 Nm (204 kgf-cm, 15ft-lbf)
NOTICE: The acceptable installation angle of the sensor is between 7° upward and 10° downward from the horizontal position.

(b) Connect the sensor connector.
2. INSTALL INTAKE MANIFOLD
(a) Install the intake manifold Installation.