After-Run Coolant Pump: Testing and Inspection
After-run coolant pump, checking
Special tools, testers and auxiliary items required
^ Diode test lamp V.A.G 1527 B
^ Adapter set V.A.G 1594 A
^ Wiring diagram
Requirements
^ Fuse No. 16 OK
Work sequence
- Disconnect 2-pin connector from After-run coolant pump -V51-.
- Connect contacts of After-run coolant pump -V51- to battery using auxiliary cables from V.A.G 1594 A.
- After-run coolant pump must start.
If after-run coolant pump does not start:
- Replace After-run coolant pump -V51-.
If the After-run coolant pump -V51- starts:
- Switch ignition off and on again.
- Connect diode test lamp V.A.G 1527 B to disconnected connector of After-run coolant pump -V51- with auxiliary cables from V.A.G 1594 A.
- LED must light up
Note:
^ This check must be performed within 10 minutes after switching ignition off.
If LED does not light up:
- Locate and eliminate open circuit referring to wiring diagram.