Integrated Control Unit (ICU) - Installation
INSTALLATION
1. Position the Integrated Control Unit (ICU) (3) and insert mounting pin into body hole (1).
2. Install mounting screws (5) and tighten to 23 Nm (17 ft. lbs.).
CAUTION: Before installing the ABM harness connector on the ABM, be sure the seal is properly installed in the connector.
3. Insert the ABM wiring harness connector (2) into the socket of the ABM (1) and close the cover, locking the connector in place.
4. Install the four chassis brake tubes (2, 3, 5, 6) brake tubes at the ICU hydraulic control unit (7). Tighten the tube nuts to 17 Nm (150 in. lbs.).
5. Install the primary (4) and secondary (1) brake tubes at the ICU hydraulic control unit (7). Tighten the tube nuts to 17 Nm (150 in. lbs.).
6. Remove the brake pedal holding tool.
7. Install the engine appearance cover.
8. Reconnect the negative battery cable.
9. Install a scan tool to initialize the ABM and perform the following:
a. Clear any faults.
b. Fill the master cylinder to the proper fill level and bleed the base and ABS hydraulic systems Service and Repair.
c. Check for leaks.
10. Perform the Verification Test and clear any faults Verification Tests